Filter Results By:

Products

Applications

Manufacturers

Current Shunts

Resistors with known accurate values to measure current.

See Also: Shunts, AC Current Shunts


Showing results: 46 - 60 of 69 items found.

  • Current Sensing Resistors: ACQ-200

    TCS - RARA Electronics Corporation

    These components are four-terminal. bus-bar, metal strip current shunts. Assembled using electron beam welding. These units can handle 15W of continuous power and a maximum current of 350A 90.1mohm). Also they can absorb a high pulse power rating and have very low inductance. They also feature excellent long term stability, less than 100ppm/C TCR, and have excellent frequency characteristics.

  • DC Electronic Loads

    Keysight Technologies

    Keysight DC electronic loads provide you with the flexibility to test a wide range of applications from power-supply test to simulation of high-intensity discharge (HID) headlamps. The 16-bit voltage, current and power-measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.

  • Data Acquisition Recorders & Loggers

    DAS1800 - B&K Precision Corporation

    The DAS1800 can be configured for a wide variety of applications with slots for 10 input modules each supporting 4 or 8 measurement channels. Acquire data from any sensor with a voltage or current output (with shunt), or directly measure voltage, resistance, or temperature using thermocouples or resistance temperature detectors (RTDs).

  • Current Sensors

    Measurlogic

    Measurlogic offers an array of current sensors for every need, including split core, solid core and Rope current transformers (CTs); DC Shunts and Hall Effect Sensors. All of our electrical sensors are designed with an easy, un-intrusive installation in mind. With a low cost and high accuracy guarantee, we provide top of the line solutions for measurement and cost savings for residents and business owners alike.

  • Reactor Loss Measurement Systems

    Measurements International Ltd.

    The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.

  • Ungrouped

    Weshine Electric Manufacturing Co., Ltd

    The instrument can measure single capacitor of single phase or three-phase shunt capacitor bank without removing wires.2. The instrument has the functions of inductance, resistance and current measurement.3. The instrument has two power supply modes: External AC220 V and built-in lithium battery meet various application scenarios.

  • Capacitance Bridge

    Guildline Instruments Ltd

    Capacitance Bridge is an instrument employing the AC Current Comparator principle. The 9910A is a versatile instrument for a wide range of applications including capacitance measurements, cable testing, corona loss measurements, insulator and dielectric testing, inductance measurements, potential transformer error measurements, shunt reactor loss measurements and power transformer testing.

  • Built-in Measuring Instruments

    PeakTech Prüf- und Messtechnik GmbH

    Practical built-in module as voltmeter with freely definable measuring range from 0 to 200mV, 2V, 20V, 200V or 500 V. Current measurements from 0 to 200µA, 2mA, 20mA, 200mA and 2A can be carried out via a shunt. With the snap-in frame, this inexpensive module can be integrated into any front panel of your own construction.

  • NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    783311-01 - NI

    ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.

  • Dual Wide Range Power Monitor

    LTC2992 - Analog Devices Inc.

    The LTC®2992 is a rail-to-rail system monitor that measures current, voltage, and power of two supplies. It features an operating range of 2.7V to 100V and includes a shunt regulator for supplies above 100V. The voltage measurement range of 0V to 100V is independent of the input supply. Two ADCs simultaneously measure each supply’s current. A third ADC monitors the input voltages and four auxiliary external voltages. Each supply’s current and power is added for total system consumption. Minimum and maximum values are stored and an overrange alert with programmable thresholds minimizes the need for software polling. Data is reported via a standard I2C interface. Shutdown mode reduces current consumption to 25μA typically.

  • Digital Power Meter, 30A

    66205 - Chroma Systems Solutions, Inc.

    Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface

  • Current Sensing

    Texas Instruments

    voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.

  • Series Voltage References

    Analog Devices Inc.

    Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.

  • Multiphase Power Analyzer

    2800 Series - Valhalla Scientific Inc.

    The Valhalla Scientific 2800 High-Precision Power Analyzer is available in 1-, 2-, 3-, 4-, 5-, or 6-phase versions.  All voltage inputs 0.3V up to 1500V peak and all current inputs 1.5mA up to 1A; 15mA up to 5A; 1A up to 40A; and shunt inputs 60mV up to 6V are potentially free and exhibit low noise, high common mode suppression, excellent DC-stability, wide frequency range (DC-2MHz) and very low self-heating on current inputs.There is no need to fiddle with DC-compensation, or changing current plugging.  All is built into the input sections of the power analyzer, ready for measurements.  It is simple to use, your intuition will guide you to operate the Power Analyzer touch screen correctly.

  • Electrical Standards

    Fluke Calibration

    To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.

Get Help